Have you considered how to start generator without pull cord? You can use a power drill or a cordless impact driver to start a generator when there is an issue with the pull cord. Also, you will need a socket, and with some battery power remaining, it is possible to get started within a short time. If you’re in the middle of a thunderstorm and a massive lightning strike has rendered your area powerless, or if the government is unable to provide enough power, you should consider having a generator on hand.
But what if, in your desperate attempt to reactivate the power, you accidentally break the pull cord? Are you doomed to fail? Is there a way to start the generator without using the cord?
When your generator pull cord breaks, you can start it with a drill instead of the pull cord. All you’ll need is a power drill and a socket that fits into the generator’s nut attachment.
Is It Safe To Start A Generator Without A Pull Cord?
It’s safe to use the generator without a pull cord, but you have to be careful. To power up the generator, simply connect the drill to the nut attachment and turn it on. If you want to manually start a generator, you can use a power drill.
There are, however, other ways to start your generator under $300 bucks that do not necessitate the use of a power drill. The rope that you (accidentally) broke is used in the majority of these methods. What are the chances that your generator won’t start if these methods don’t work? All of this is investigated.
How to Start a Generator without a Pull Cord?
If you don’t have access to a substitute pull cord, you can run your generator with just a power drill (or a cordless impact driver), a suitable socket, and some remaining battery power. After you’ve gathered these items, you’ll need to take the following steps:
- Remove the generator recoil starter motor’s shroud (cover) to see what kind of nut attachment is located in the centre of the (pull) starting mechanism.
- Find out what the nut’s size is and what kind of socket you’ll need to connect to it. Because most manufacturers use different-sized nut attachments, you’ll want to have as many sockets as possible on hand to test them.
- You can connect a ‘breaker bar connector’ to the power drill (or impact driver) you brought once you’ve determined the size of the socket. Set the drill to a low speed and insert the socket into the breaker bar connector’s end.
- Turn the drill on and let it spin the nut at a high speed.
- It may take a few tries and rotations, and you may need to fiddle with the priming system (or even the choke on your generator), but your generator should eventually start.
So by following these steps, you have started your generator manually without using a pull cord. Hence, you have learnt
how to start a generator with a drill.
Is It Possible To Start A Generator With A Broken Pull Cord?
If you don’t have a power drill and your cord has snapped, there’s still hope. Some generators, but not all, allow you to start your generator even if the rope is broken.
You’ll need to remove the shell from the starting mechanism for this to work. The nut attached in the middle of the mechanism, as well as a flywheel that can turn around it, can now be seen. You’re lucky if this flywheel has a tiny notch (meaning a small hook).
Tie an appropriate-sized knot with the remaining piece of rope you have, or even a longer cord if you have any on hand. Hook the knot on the notch and wrap the rope as tightly as possible around the wheel. You’ll notice that if you pull hard on this rope, the wheel spins quickly and powers the generator. Your generator will start if you pull hard enough.
If the flywheel does not have a notch around which the rope must pass, the rope will not stick to the flywheel and turn it once pulled. As a result, without the notch, this method will fail.
It’s worth noting that some people prefer this method of starting their car over the traditional one. Some argue that using a drill is potentially dangerous.
Is It Possible To Repair A Generator’S Broken Pull Cord?
If you’re lucky, there might still be a sliver of pull rope left when you open the generator’s housing. In this case, you’ll need to tie a very strong knot to connect the two broken ends of the rope. Make sure that whatever knot you choose is nearly unbreakable.
Guide the new rope through the generator in the same way that the old rope did, then tie it to a handle and use it to start the generator!
This is not a long-term solution, but it will get the job done if you desperately need power – it will start your generator.
Unfortunately, you won’t be able to fix the pull cord on your generator as described above if there is no rope left inside the generator.
Reasons Why Your Generator Fails To Start
If you’ve tried making another roper, using the same cord attached directly to the flywheel, and using a drill to start your generator, and it still doesn’t work, one of the following possibilities exists:-
There isn’t enough oil in the generator. You must inspect the crankcase to determine the oil levels in your generator. It’s important to keep in mind that uneven surfaces can cause your oil sensor to give you inaccurate readings.
It has run out of gas. This is the most obvious, and you should check your gas tank to see if your generator is running low on gas.
Your spark plug isn’t working properly. Your sparkplug may be full of buildup if you’ve been using your generator for a long time.
Your generator’s battery is dead. If you have an electric start generator, there’s a chance the battery won’t have enough charge to start the engine.
Your generator’s carburettor could be clogged. This can happen if fuel is left in the generator for an extended period and the generator is not used. This may cause some of the substance to clog your carburettor, in which case you should simply try cleaning it. If cleaning does not solve the problem, you may need to consider replacing it.
Final Word
After learning how to start generator without pull cord, you are now in a better position if the unexpected happens. Nothing can stop you from having an uninterrupted power supply, either from the mains or your generator. Also a ipower generator is available.